powerful
and compact
technology

SWITCHING REAL TIME

Mectronic uses innovative Switching Real Time technology for Doctor Tecar.
Thanks to this important step forward in technology it is possible to reach high power and increased therapeutic performance.
Switching Real Time technology has also allowed the dimensions of the device to be reduced. Doctor Tecar is compact, high power, and easily transportable.
Doctor Tecar: SWITCHING REAL TIME
technology

THE REAL POWER

Doctor Tecar is light, powerful, compact and easy to transport. 120 W of effective power (350 Wpp) in both resistive and capacitive mode in a device which weighs just 2 kg: the most powerful technology in a solid, practical and compact design.
Doctor Tecar: THE REAL POWER
technology

MULTI FREQUENCY

Thanks to Mectronic’s Real-Time Switching technology Doctor Tecar uses two separate frequencies - the lower for the Resistive Mode (450 kHz) and the higher frequency for the Capacitive Mode (600 kHz), maximising therapeutic effects. The AVx mode gives access to a third working frequency which is ideal for automatic treatments.
Doctor Tecar: MULTI FREQUENCY
technology

FROM RESISTIVE TO CAPACITIVE
IN A SINGLE CLICK

Thanks to Real-Time Switching technology and the innovative MecOS 2.0 software, it is possible to go from resistive to capacitive mode and vice versa with a simple command, without changing handpiece or applicator. Simplicity, speed and high-performance are just some of the strengths which make Doctor Tecar a valuable ally in day-to-day practice.
Doctor Tecar: FROM RESISTIVE TO CAPACITIVE IN A SINGLE CLICK
technology

ADJUSTABLE PULSED MODE

During the treatment of pathologies involving skeletal muscles during the acute phase, an excessive increase of the effects of active hyperemia can cause vasodilatation which leads to increases sensitivity in the pain receptors, generating patient intolerance of the therapy. To reduce this, Doctor Tecar features the Adjustable Pulsed Mode. With this mode the energy supply is carried out at regular time intervals.

The pauses (TOFF) between one pulse and the next (TON) allow the energy administered to the tissues to be controlled, maintaining ‘comfort heat’ conditions which favour correct cellular homeostasis. In this way unwanted side effects such as increased pain can be avoided. Furthermore, the Adjustable Pulsed Mode of Doctor Tecar allows the operator to personally set the times for supply and pause (TON and TOFF), guaranteeing made-to-measure therapy for every patient. It is possible to work in Thermal, Comfort Heat, and Heat-Free modes.
Doctor Tecar: ADJUSTABLE PULSED MODE
Doctor Tecar: ADJUSTABLE PULSED MODE
Doctor Tecar: ADJUSTABLE PULSED MODE
technology

AVX MODE

With AVx mode tecar therapy will never be the same: with three new modes designed to meet the needs of the therapist, Doctor Tecar transforms into a single platform which is able to best support therapeutic activity.

The Automatic mode has been designed to allow the therapist to be free of the manual use of tecar therapy: the special cable and three electrodes allow even complex shaped areas of the body to be treated.

The Automatic Pulsed mode was created from the combination of the Automatic and Adjustable Pulsed modes; a therapy which, thanks to pulsed supply, avoids rises in temperature and allows a more focused treatment.

The Transport mode allows the deep absorption of active substances through the energetic transfer of Tecar therapy.
Doctor Tecar: AVX MODE
technology

APPLICATORS WITH DT-MAS TECHNOLOGY

Changing the applicator is a frequent operation which can be tricky when the operator has cream on their hands. For this reason Mectronic has designed and patented its magnetic DT-MAS (Doctor Tecar Magnetic Attachment System) system to make the operation simple, quick and effective.
Doctor Tecar: APPLICATORS WITH DT-MAS TECHNOLOGY
technology

BIOCOMPATIBLE COVER PROTECTION

Mectronic believes that the health and safety of both patients and operators is of fundamental importance. Not only are all technological means employed to make therapy safe and effective, but thanks to feedback from operators and continuous research, we aim for constant innovation and improvement. Therefore Mectronic has fitted its Doctor Tecar devices with a cover in certified biocompatible plastic material to insulate the operator from the applicator during therapy, making treatments safer and more effective.
Doctor Tecar: BIOCOMPATIBLE COVER PROTECTION
Receive more information on Doctor Tecar
Fill the form below to have informations on Mectronic products
*
*
*
*
Mectronic Medicale Mectronic Medicale
Request sent successfully
Thank you for contacting us. Our operator will contact you shortly.
Sei un professionista del settore?
L'accesso alla visualizzazione dei prodotti e al materiale informativo è riservato agli operatori del settore in ottemperanza alla legislazione vigente. Mectronic Medicale richiede di qualificarsi come professionista per procedere con la navigazione.
Sono un professionista
Keep you up to date
about news of Doctor Tecar
Subscribe to the newsletter and keep you up to date about products, courses and all the news.